Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Registryoperationalinfo
Wu_req_form_requireNo
uoidION-8139
Work_scheduleMON-FRI
Wu_HHSQ_formYes
Wu_req_patient_requirYes
Prelim_search_reqNo
Post_direct_contactNO
Donor_ID_exampleNLxxxxxxxx or NLxxxxxxxD or 8139 xxxx xxxx xxxx xxx
orgnameMatchis Foundation
Registry_closures1-JAN-2016;28-MAR-2016;5-MAY-2016;16-MAY-2016;26-DEC-2016
reviewyear2025
Time_zoneEurope/Amsterdam (GMT+01:00)
Post_anony_contactAnonymous postcards or letters
Subsequent_donationAllowed, under supervision of Medical Advisory Board
Ext_type_reqNo
Ext_type_optionHR,LR,IR, A,B,C,DR,DP,DQ,DRB1
Verif_days_reserved2 weeks90 days
Business_hours8:30 - 17:00
Post_gift_excYES, small presents and not valuable
Post_cbb_contactN.A.
Sibling_typeYes
Wu_idm_completeYes
Wu_req_limit_dosdepends on donor
Verif_reqNo
Verif_req_max_vol100
Ext_type_days_reserved90 days
Sibling_procedureBy email request; then we will ask you to complete WMDA forms (they will be sent to you)
Wu_req_ext_pat_infoSee minimal criteria document
Verif_idm_completeYes

idmcmvigm
Regsurvey_idm
idmmethodstsftaabsChemiluminescence Immunosorbent (CLIA) - Architect - HIV score blotidmmethodhtlvi
On requestidmmethodcmvigmChemiluminescence Immunosorbent (CLIA) - Architect
idmother Yes
idmcmvtotalNo
idmcmvtotalidmdaysvzvOn requestat WU
idmmethodcmviggChemiluminescence Immunosorbent (CLIA) - Architect
idmmalariaOn request
idmmethodhcvabChemiluminescence Immunosorbent (CLIA)
idmchagasOn request
idmdayshevnatat WU
idmhiv1ab Yes
idmwnvnatOn requestonly at positive STS serology - TP Architect - lues blot Fujiredio
idmhiv2ab Yes
idmmethodhiv2abidmmethodhiv1abChemiluminescence Immunosorbent (CLIA) - Architect - HIV score blot
idmmethodhevnatQualitative RT-PCR
idmaltast Yes
idmcmvigg Yes
idmdaysmalariaat WUidmmethodhivnatQuantitative RT-PCR
idmhivnat Yes
idmhtlvi Yes
idmhbsag Yesidmmethodhsvserology or PCR - Diasorin Liaison XL HSV IgG
idmebviggOn request Yes
idmsts Yes
idmvzvOn request
idmmethodebviggChemiluminescence Immunosorbent (CLIA) - Liaison
idmhcvnat Yes
idmmethodhbcabChemiluminescence Immunosorbent (CLIA)
idmmethodhcvnatQuantitative RT-PCR - Cobas Taqman
Chemiluminescence Immunosorbent (CLIA) - Architect - ImmunoblotidmmethodtoxoplasmChemiluminescence Immunosorbent (CLIA)
idmhbcab Yes
idmhivp24On request Yes
idmebvigmOn request
idmdayshsvat WUidmmethodhbsagChemiluminescence Immunosorbent (CLIA) - Architect
idmmethodebvigmChemiluminescence Immunosorbent (CLIA) - Liaison
idmmethodmalariaserology or PCR
idmdayscmvigmat CT / WU
idmdayshivp24at CT/WUidmhtlvii Yes
idmhbvnat Yes
idmmethodhivp24Chemiluminescence Immunosorbent (CLIA) - Architect - HIV score blot - HIV duo ultra (VIDAS)idmmethodhtlviiChemiluminescence Immunosorbent (CLIA) - Architect - Immunoblot
idmstsftaabsOn request
idmmethodotherDenque NS1 Ag; Denque PCR, Zika PCR, Qfever phase 2 ab
idmmethodstsChemiluminescence Immunosorbent (CLIA) - TP Architect - lues blot (INNO-LIA innogenetics ) RPR titratie
idmmethodvzvChemiluminescence Immunosorbent (CLIA) - Diasorin Liaison XL VZV IgG
idmhcvab Yes
idmmethodhbvnatQuantitative RT-PCR
idmhsvOn request
idmmethodhbvnatQuantitative RT-PCR
idmcmvigmOn request
idmdaystoxoplasmat WU
idmdaysebviggat WU
idmdaysebvigmat WU
idmmethodstsftaabsonly at positive STS serology - TP Architect - lues blot Fujiredio
idmdayschagasat WU
idmhiv2ab Yes
idmtoxoplasm Yes
idmmethodchagasserology
idmmethodhiv1abChemiluminescence Immunosorbent (CLIA) - Architect - HIV score blot
idmhevnat Yes
idmaltast Yes
idmcmvigg Yes
idmdayswnvnatat WU
idmmethodhivnatQuantitative RT-PCR
idmmethodhsvserology or PCR - Diasorin Liaison XL HSV IgG
idmmethodhtlviChemiluminescence Immunosorbent (CLIA) - Architect - Immunoblot
idmmethodhbsagChemiluminescence Immunosorbent (CLIA) - Architect
idmmethodmalariaserology or PCR
idmhtlvii Yes
idmmethodhtlviiChemiluminescence Immunosorbent (CLIA) - Architect - Immunoblot
idmhcvab Yes

Regulatory information

Regsurvey_block1
dp_consent yes
prod_internatnrhpccb0
aff_cbnrno
aff_listonrequest yes
aff_additionalreqtxtFor the national Transplant centers: License for transplantation with unrelated HPC donor and JACIE accreditation
lic_accredotherorgnameISO27001/NEN7510 certification - data protection
prod_natnrhpca2821
aff_hlalabauditnot standard procedure
aff_certificcopy yes
prod_natnrhpcm92
reviewyear20242025
lic_compdate2024/01
aff_additionalreq yes
aff_tcnr9
dp_informed yes
lic_wmdaWMDA Accredited
aff_dcnr0 (Donor centre is a department of the Registry (operating in Leiden and Nijmegen)
prod_hpccbno
aff_hlalabnr32
orgstartyear1988
dp_anonymous yes
orgcountryThe Netherlands
prod_ncwbno
prod_mnca yes
prod_hpcm yes
orgionION-8139
prod_hpccbcommRequests for Dutch CBU is forwarded to Sanquin ION-1131
aff_ccnr2
dp_recordsecurity yes
lic_legalprovide yes
dp_evalexcludewmda yes
orgnameMatchis Foundation
prod_hpca yes
prod_internatnrhpcm1918
aff_ccaudityes
lic_accredother yes
aff_tcauditno, Transplant centers in the Netherlands are JACIE accredited. Compliance statements to WMDA standards are required
prod_natnrhpccb0
lic_compnameMinistry of Health, Welfare, Sport; Inspected by IGJ
dp_unpaidvolunteers yes
lic_compwebhttps://www.government.nl/ministries/ministry-of-health-welfare-and-sport
aff_idmauditnoyes
aff_idmnr3
prod_internatnrhpca209136
aff_cbauditno
lic_comp yes
aff_complywmda yes
aff_dcaudityes, internal audits
dp_evalexludecrit yes
prod_statyr20232024
lic_compcommTissue establishment license

...

Regsurvey_block3
qm_packageshare yes
test_questexcllifestyle yes
test_eu200617EC yes
sear_natmand yes
sear_wmda yes
test_examdr yes
test_hlatypaccred yes
cust_importregMatchis is licensed to import HPC into the Netherlands and follows strict Matchis safety policies
test_steriledp yes
qm_sop yes
qm_sopshare yes
cust_custexportStandard procedure for export: Prior to shipment notification to customs and security; to accompany the product: Collection report, collection details, Transport Audit form, Transplant report, confidentiality policy, if for NMDP: IDM's, declaration of donor eligibility
sear_24hrnotice yes
test_idmlabcert yes
test_questexclcomdis yes
test_reliabilitydr yes
cust_custimportNo specific custom regulation for import cells out of into the Netherlands
qm_yrretain30

...