You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 15 Next »

DRAFT

For the fields without extra explanation in this page, then the fields explanation in the XML fields explanation (https://share.wmda.info/x/MYCOD) or data dictionary tool (https://datadictionary.wmda.info/) is enough.  


TNC_FRZN

Field information

TNC_FRZN TNC_FRZN is an important parameter in finding a matching CBU, next to HLA.

In order to help to monitor not only the density but also the correctness of the value for TNC_FRZN, the data distribution is needed.

Based on WMDA global trend report and feedback from some registries, we improved the castigates as below:

Data unit 10^7

[1-49][50-89][90-124][125-149][150-199][200-249][250-299][300-699][700-max]



CD34PC_FRZN

Field information

CD34PC_FRZN is an important parameter in finding a matching CBU, next to HLA.

In order to help to monitor not only the density but also the correctness of the value for CD34PC_FRZN, the data distribution is needed.

CD34PC_FRZN value range is defined as below, may still need improvement:

Data unit: 10^6

[-1-0]*[1-9][10-19][20-29][30-49][50-max]

*: "-1" means the value is less than 1.0x10^6.

VOL_FRZN

Field information

In order to help to monitor not only the density but also the used volume in each organisation, the VOL_FRZN data distribution is needed.

VOL_FRZN value range is defined as below, may still need improvement:

Data unit: ml

[0-19][20-29][30-49][50-59][60-99][100-129][130-169]

VIABILITY

Field information

The VIABILITY of TNC_FRZN is required for FACT accredited CBBs.  The value should be >85 for FACT accreditation. Source : http://www.factwebsite.org/CBStandards7thEdition/ page 85, appendix 5

Value range is defined as below, may still need improvement:

Data unit: %

[0-74][75-84][85-90][91-95][96-100]

CONTACT_DATE

Field information

Contact date is the last date there was contact between the registry and the Donor.

This date is an important indicator for the ...



NMBR_MARR

Field information

Number of marrow donations. Technically, it is possible for donor to donate many times. But so far, we consider 3 times as the maximum. So all number larger than 2 must be checked, corrected and deleted. 


NMBR_PBSC

Field information

Number of PBSC donations. Technically, it is possible for donor to donate many times. But so far, we consider 3 times as the maximum. So all number larger than 2 must be checked, corrected and deleted. 


NMBR_TRANS

Field information

Number of blood transfusions. 


  • No labels